Field Service Ver. 1.1 May 2011
Two-way communication
Step
6
Encryption setting
1. Select [SERVICE MODE] [PS / PCL] [CS REMOTE CARE] [BASIC SET-
TING] [ENCRYPTION].
2. Select [YES] or [NO] according to the necessity of encryption, and press the Select key.
7
Heart Beat *1
1. Select [SERVICE MODE] [PS / PCL] [CS REMOTE CARE] [CSRC SET-
TINGS] [HEARTBEAT SETTINGS].
2. In [ENABLE HEATBEAT], set whether or not to enable Heart Beat communication. (Default:
YES)
3. Select [INTERVAL] and enter a Heart Beat transmission interval (1 to 256 minutes, Default: 30
minutes).
4. In [ENABLE FIXED TIME], set whether or not to enable Heartbeat transmission at a fixed
interval. (Default: Yes)
5. Select [FIXED TIME] and enter a Heartbeat transmission interval (1 to 256 minutes, Default:
30 minutes).
8
Proceed to step 10.
9
10 Setting the http server
1. Select [SERVICE MODE] [PS / PCL] [CS REMOTE CARE] [BASIC SETTING] [WEB
SERVER]
2. Input the server name of the CS Remote Care center, and press the Select key.
3. Select [SERVICE MODE] [PS / PCL] [CS REMOTE CARE] [WEBDAV SETTING], and
make the settings of communication with the server according to the network environment.
See P.180
11 Enables/disables some special warning and report functions
1. Select [SERVICE MODE] [PS /PCL] [CS REMOTE CARE] [CSRC SET-
TING] [SWITCHES SETTING], and set whether or not to enable each function.
See P.182
12 Executing the initial transmission
1. Select [SERVICE MODE] [PS /PCL] [CS REMOTE CARE] [SUBSCRIBE].
2. Select [YES], and press the Select key to start initial transmission.
*1 Heartbeat is a feature that uploads a Heartbeat file to the registered web server at a
specified interval to report that the device is operating. Heartbeat files include total
counter and status information.
One-way communication
Procedure
Periodic transmission setting
1. Select [SERVICE MODE] [PS/PCL] [CS
REMOTE CARE] [CSRC SET-
TING] [PERIODIC TRANS.].
2. In [ENABLE TRANS.], set whether or not to
enable periodic transmission.
(Default: On)
3. Select [INTERVAL], [TIME], [DAY OF THE
WEEK] or [DATE] and set the schedule of
periodic transmission.
See P.182
Report setting
1. Select [SERVICE MODE] [PS / PCL] [CS
REMOTE CARE] [CSRC SET-
TING] [REPORT SETTING].
2. Select the report item and set items that will
be reported to the Center.
See P.182
13. SERVICE MODE