Opening and closing the housing

7 Opening And Closing the Housing
DANGER
CAUTION
NOTICE

7.1 Removing and Attaching the Side Wall

7.1.1 Removing the Side Wall

20
Risk of Personal Injury and Property Damage from Electric Shock
• Before working on the unit's housing, ensure that the unit is not connected to
an electrical outlet.
• Do not operate the unit with the housing open.
• Wear protective gloves.
Risk of Property Damage from Damage to The Lines
• Remove and attach housing components carefully.
Image: Removing the side wall
1. Remove the screws on the trolley handle holder using a flat-head
screwdriver.
2. Remove trolley handle holder.
3. Remove the screws at the bottom of the side panel using a 7 mm
hexagon screwdriver.
4. Pull the bottom edge of the side wall forward.
5. Remove the side wall.