Performing maintenance
8.5 Check Housing
Check unit spacers
Test criteria
• Spacers are in place and have contact with the wall.
Check hand shower
Test criteria
• Hand shower is not leaking and works properly.
If No
Change hand shower.
Check hose reel and hose
Test criteria
• Hose is free of cracks and works properly.
If No
Replace hose reel.
Check steam diverter
Test criteria
• Steam diverter is present on top of the unit.
8.6 Check Cooking Chamber
8.6.1 Supply Air Supply Cooking Chamber
Check the air supply to the cooking chamber and check air supply to lift magnet
Test criteria
• Supply air opening on the top of the unit is free (air flow is not restricted or obstructed).
If No,
Clean the supply air inlet.