Check contactor
Test criteria
• Contactor is externally OK (not brittle, damaged, or charred) and screw connections are tight.
If no,
Troubleshoot and replace parts as necessary
Please provide remarks here and attach pictures to warranty claim.
Inspecting the permanent connection for visible damage
Test criteria
• Electrical connection line is installed correctly, and wire insulation is undamaged (not brittle or scorched).
If no,
Troubleshoot and replace parts as necessary.
Please provide remarks here and attach pictures to warranty claim.
Check electrical contacts - Carry out inspection of wiring harness (cable and contacts)
Test criteria
• Contacts are free of scorch marks.
If no,
Troubleshoot and replace parts as necessary.
Please provide remarks here and attach pictures to warranty claim.

8.12 Check Components

Checking fan (service level / relay test K11)
Test criteria
• All fans work properly when the cooking process is active.
If No
Troubleshooting according to service manual.
Check lift magnet air inlet flap (service level / relay test K08)
Test criteria
• Lift magnet works perfectly.
If No
Troubleshooting according to service manual.
Inform operator.
Check the steam injection unit (see Service level / Relay test K04)
Test criteria
• Humidification unit works perfectly.
If No
Troubleshooting according to service manual.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No