EWM Tetrix 352 AC/DC Synergic Operating Instructions Manual page 69

Power source
Hide thumbs Also See for Tetrix 352 AC/DC Synergic:
Table of Contents

Advertisement

Display
for AC welding machines only.
1
For machines with filler wire (AW) only.
2
only for machines with an interface for automated welding or appropriate automation components.
3
099-000140-EW501
30.01.2024
Setting/selection
Reset (to factory setting)
-------Disabled (ex works)
-------Reset the values in the machine configuration menu
-------Complete reset of all values and settings
Resetting is performed when exiting the menu (
Automated/Manual (rC on/off) operating mode
Select machine/function control
------with external control voltages/signals
------with machine control
Software version query
System bus ID and version number are separated by a dot.
Example: 07.0040 = 07 (system bus ID) 0.0.4.0 (version number)
Cable resistance alignment > see 5.10 chapter
Only qualified service personnel may change the parameters!
TIG HF start (soft/hard) switching
-------soft ignition (factory setting).
-------hard ignition.
Ignition pulse limit
Setting 0 ms–15 ms (increments of 1 ms)
PCB state – qualified service personnel only!
Design and function
Machine configuration menu
).
3
69

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tetrix 352 AC/DC Synergic and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents