Design and function
Power-saving mode (Standby)
5.7
Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button > see 5.9 chapter for a pro-
longed time or by setting a parameter in the machine configuration menu (time-controlled power-saving
mode
) > see 4.2 chapter.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. turning a rotary knob) deactivates power-saving mode and the ma-
chine is ready for welding again.
5.8
Access control
These accessory components can be retrofitted as an option > see 9 chapter.
To protect against unauthorised or unintentional adjustment of the welding parameters on the machine,
the control input can be locked with the aid of a key switch.
Key position 1 =
Key position 0 =
64
All parameters can be set
Only the following operating elements are functional:
•
"Operating mode" button
•
"Welding parameter setting" rotary transducer
•
"Display switching" button
•
"TIG pulse welding" button
•
"Select welding parameters" button
•
"Gas test" button
099-000140-EW501