DIP Switch
Location
Left door
3.9.1 Setting DIP Switches
Warning:
Be sure the welder is electrically disconnected before
opening the cover.
Open the welder's left-side cover to access the DIP switches. After altering
a DIP switch, close and secure the left-side cover and plug in the power
cord.
SW2 - 8 State Display Status — When ON, allows state digits (for example,
State 1) to appear on the display, in place of weld time values when OFF.
This display is in addition to the mode LEDs.
SW2 - 5 Display Lock — When ON, prevents any changes from being
made to weld parameters except TEST, HOLD, and HORN DOWN.
However, all parameters relating to the current weld mode are displayed
and you can still restore cold start parameter values.
SW1 - 8 Units Status — When ON, selects SI units (mm), otherwise OFF
selects USCS units (in).