Warning name
Warning display
Analogue input
warning
(Over signal)
(No signal)
Waiting for the start of
local control operation
(Control start wait)
Outside the output PD
range
(PD out of range)
Description
Analogue input has exceeded
110%F.S. of the rated control
flow range.
Analogue input is below
-5%F.S. of the rated control
flow range.
Stand-by state until the mode
shifts to measurement mode
after the power is turned on.
(When [Local] is selected in
the control selection setting
mode)
The output PD of the
commanded flow rate is
beyond the range of 0 to 4120.
-71-
Measures
operation in the
event of an error
Continuing
Make sure that the
analogue input is
within the set flow
rate range.
Continuing
Start the operation
of the product after
the stand-by time
has elapsed.
Make sure the
output PD of the
Value before the
commanded flow
rate is within the
range of 0 to 4120.
No.PF※※-OMA1002
Control
Stop
event