SMC Networks PFCA7 Series Operation Manual page 63

Flow controller for air
Table of Contents

Advertisement

●Product original parameter
Index
Sub
Access
1
index
dec
hex
Units
1000 0x03E8
0
R/W
(Units setting)
CoL
1010 0x03F2
0
R/W
(Display colour selection)
NorP
1020 0x03FC
0
R/W
(Selection of switch output
PNP/NPN)
FLU
1060 0x0424
0
R/W
(Fluid)
rEF
1070 0x042E
0
R/W
(Reference condition)
OUT1_mode
1210 0x04BA
0
R/W
(Selection of OUT1 output
mode)
ToL1
1
R/W
(Setting of OUT1 limit
deviation tolerance)
7210 0x1C2A
On Delay1
2
R/W
(OUT1 on-delay time)
Off Delay1
3
R/W
(OUT1 off-delay time)
OUT1_AC_L
1300 0x0514
0
R/W
(Accumulated threshold
value setting L)
OUT1_AC_ft
1310 0x051E
0
R/W
(Accumulated threshold
value cfm)
Inc_Dec
1600 0x0640
0
R/W
(Accumulation direction
setting)
Line name ON/OFF
1
R/W
(Line name display)
2000 0x07D0
Sub display
2
R/W
(Sub display setting)
Data
Initial
Parameter
type
value
2
U8
0
U8
1
U8
1
U8
0
U8
0
U8
0
U16
3
U16
0
U16
0
U32
0
3
U32
0
U8
0
U8
0
U8
0
-63-
Data
4
storage
Setting value
3
0: L/min (L)
Y
3
1: cfm (ft
)
0: white
(Always white characters)
1: 1onBoffR
(Blue background at on)
2: 1onRoffB
Y
(Red background at on)
3: 1onGoffR
(Green characters at on)
4: 1onGoffR
(Red characters at on)
0: NPN
Y
1: PNP
0: Air (Air)
Y
1: Argon (Argon)
2: CO
(Carbon dioxide)
2
0: STD (Standard condition)
Y
1: NOR (Normal condition)
0: Tolerance
(Limit deviation tolerance)
1: Accum(P)
(Accumulated output normal)
2: Accum(N)
(Accumulated output reverse)
Y
3: Pulse(N)
(Accumulated pulse normal)
4: Pluse(P)
(Accumulated pulse reverse)
5: Alarm(NC) (Error output)
6: AlwaysOFF (Output OFF)
Setting range
Y
0 to 50
Setting range
Y
0 to 6000
Setting range
Y
0 to 6000
Setting range
Y
0 to 999999999
Setting range
Y
0 to 999999999
0: Increment (Addition)
Y
1: Decrement (Subtraction)
0: OFF
Y
1: ON
0: Set value
1: Peak/Bottom
Y
2: Accumulate valu
3: IO-Link mode
4: Line name
Remarks
When the units selection function is
not available, read/write to an
unselectable item is rejected.
Display colour setting
Setting of the switch output
specifications
Reference condition setting
Setting of OUT1 output mode
Set the OUT1 on-delay time
10 ms unit
Set the OUT1 off-delay time
10 ms unit
Unit specification when (Unit):
"L/min" is selected
Unit specification when (Unit): "cfm"
is selected
No.PF※※-OMA1002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PFCA7 Series and is the answer not in the manual?

Questions and answers

Table of Contents