  • Page 1 Official Website APP (iOS) APP (Android) Jiangsu GoodWe Power Supply Technology Co.,Ltd ES SERIES USER MANUAL No.189 Kun Lun Shan Road, SND, Jiangsu, China. www.goodwe.com HYBRID INVERTER service@goodwe.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION 1.1 OPERATION MODES INTRODUCTION 1.2 SAFETY & WARNINGS 1.3 PRODUCT OVERVIEW INSTALLATION INSTRUCTIONS 2.1 UNACCEPTABLE INSTALLATIONS 2.2 PACKING LIST 2.3 MOUNTING 2.3.1 SELECT MOUNTING LOCATION 2.3.2 MOUNTING 2.4 ELECTRICAL WIRING CONNECTION 2.4.1 PV CONNECTION 2.4.2 BATTERY CONNECTION 2.4.3 ON-GRID &...
  • Page 3: Introduction

    INTRODUCTION 1.2 SAFETY & WARNING The ES series inverters of Jiangsu GoodWe Power Supply Technology Co., Ltd. (hereinafter called as GoodWe ES series, also called hybrid or bidirectional solar inverters, apply to solar system with GoodWe) strictly comply with related safety rules for product design and testing. Please read and participation of PV, battery, loads and grid system for energy management.
  • Page 4: Product Overview

    The temperature of inverter surface might exceed 60℃ during working, so please make sure it is cooled down before touching it, and make sure the inverter is untouchable for children. Do not open inverter cover or change any components without GoodWe’s authorization, otherwise the warranty commitment for the inverter will be invalid.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 2.3 MOUNTING INSTALLATION INSTRUCTIONS 2.3.1 SELECT MOUNTING LOCATION For inverter’s protection and convenient maintenance, mounting location for inverter should be 2.1 UNACCEPTABLE INSTALLATIONS selected carefully based on the following rules: Please avoid the following installations, which will damage the system or the inverter. Rule 1.
  • Page 6: Mounting

    • Please use DC plugs and connectors in • PV cable must be tightly crimped into the Pic 5 GoodWe accessory box connectors Step 3 • PV cable should be standard, 2.5-4mm • For Amphenol connector, the limit buckle...
  • Page 7: Battery Connection

    PV and AC power. GoodWe will keep the right for explanation on all the settings suggested and all the problems Step 1 Battery Terminal happened on lead-acid batteries or the whole system.
  • Page 8: On-Grid & Back-Up Connection

    Declaration For Back-Up Loads Step 1 GoodWe ES inverter is able to supply a continuous 4600VA output or max 6900VA in less than 10 AC Cover Connection Terminal seconds on Back-Up side to support backup loads. And the inverter has self-protection derating at high Insulator 1.Prepare the terminals and AC cables...
  • Page 9: Ezmeter & Ct Connection

    DRED is only for Australian and New Zealand installations, in compliance with Australian and New Zealand safety requirements. And DRED device is not provided by GoodWe. The EzMeter with CT in GoodWe product box is compulsory for ES system installation, used to Detailed connection of DRED device is shown below: detect grid voltage and current direction and magnitude, further to instruct the operation condition of ES inverter via RS485 communication.
  • Page 10 • SYSTEM CONNECTION DIAGRAMS NOTE:For Australian safety country, the neutral cable of On-Grid side and Back-Up side must be connected together, otherwise Back-Up function will not work. Back-Up Loads Back-Up RS485 Battery GoodWe ES Series Hybrid Inverter Main Switch Solar Array EzMeter Grid...
  • Page 11: Manual Operation

    • Wi-Fi configuration is absolutely necessary for online monitoring and after-sales maintenance Wi-Fi Reload Button PREPARATION: 1. Inverter must be powered up with only PV power 2. Need a router with available internet access to GoodWe portal www.goodwe-power.com Step 1 10.10.100.253 1.
  • Page 12: Others

    DC Injection High Inverter detects a higher DC component in AC output Try to restart inverter, check if it still happens, if not, means it is just an occasional situation or contact GoodWe EEPROM R/W Failure Caused by a strong external magnetic field etc.
  • Page 13 1.Check if there is a fluctuation on load power comply with the parameter of the battery, and 2.Check if there is a fluctuation on PV power please contact GoodWe for advices 2.For lithium batteries, BMS status is Battery Does Not Charge RUN (Solid) “Communication OK”...
  • Page 14 So if Q: Why Cannot save settings on PV Master App there is any special condition when you cannot 100% follow the instructions, please contact GoodWe A: This could be caused by losing connection to Solar-WiFi.
  • Page 15: Disclaimer

    Max. Charge Voltage (V) ≤60 (Configurable) ≤60 (Configurable) • Inverter is installed, refitted or operated in improper ways without authority from GoodWe Max. Charge Current (A) Max. Discharge Current (A) • Inverter is installed or used under improper environment or technical condition mentioned in this...
  • Page 16: Warining Quick Check List

    [5] Make sure inverter is totally isolated from any DC or AC power before connectiong AC cable,page 11 [8] GW5048D-ES:40A to inverter and backup, max 21.5A to inverter, GW3648D-ES:32A to inverter and backup, [6] Make sure AC cable is totally isolated from AC power before connecting EzMeter and CT,page 13...
  • Page 17 OTHERS OTHERS Appendix: Protection Category Definition Overvoltage Category Definition Category Ⅰ Applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low level Applies to equipment not permanently connected to the installation. Examples are appliances, portables tools and other Category Ⅱ...