Philips / Thomson Spirit / Shadow; Figure 2-18: Cable To Connect Spirit/Shadow To The 9025Tr - evertz 9025TR Series Instruction Manual

Film footage encoders
Table of Contents

Advertisement

2.13.4. Philips / Thomson Spirit / Shadow

5550 End
Parallel I/O
(Male 9 pin D)
Frame Gnd
BIPH 1
GND
BIPH 2
GND
TLC End
(Female 25 pin D)
GPO
Gnd
Gnd
6 Hz In

Figure 2-18: Cable to Connect Spirit/Shadow to the 9025TR

The signals required to connect the Spirit or Shadow telecine are found on the 9 pin D TC GEN OUT
connector (J23) on the telecine. Connect the TC Gen Out connector of the telecine to the 9 pin parallel
I/O connector of the 9025TR as shown in Figure 2-18. Retain the separate shielding of each signal up to
the 9025TR in order to prevent cross-coupling which can adversely affect the biphase reliability.
The telecine type item on the KeyLog TRACKER™ Telecine Setup screen must be set to Philips Spirit.
The film frame handling will be set to FRID Style when you set the Spirit Telecine type.
INSTALLATION
--drain--
3
--Pair 1--
6
--Gnd 1--
7
--Pair 2--
6
--Gnd 2--
J16
2
--------
14
--------
13
6 Hz Ground
7
6 Hz Input from 7750SRG
9025TR Series Film Footage Encoders Manual
9025TR End
Parallel I/O
(Male 9 pin D)
Frame Gnd
--drain--
Film Rate
1
FRID/SOF
2
--Pair 3--
BIPH 1
3
--Pair 1--
GND
6
--Gnd 1--
Def
4
Load Film
5
BIPH 2
7
--Pair 2--
GND
6
--Gnd 2--
DLO GPI
8
GND
6
-----
9
Revision 1.3
Philips End
TC Gen Out
(Male 9 pin D)
Frame Gnd
Shld
SOF
2
R
1
Ground
7
S
5
Ground
7