Wi r i n g D i a gra m s
ZN 1
GND
ZN 2
Figure 9: N/C No EOL Zone
ZN 1
GND
ZN 2
Figure 10: N/C Single EOL Zone
ZN 1
GND
ZN 2
Figure 11: N/C Split EOL Zone
1
ZN 1
GND
2
ZN 2
Figure 12: N/C Zone With Tamper
The above diagrams display zone configurations
i
using Normally-Closed Alarm contacts and
Note
Normally-Open Alarm Contacts. When using
Normally-Open Alarm Contacts you must select
Inverted Seal for each zone in MENU 3-1-8.
A shorted loop is a tamper condition for all EOL
zone configurations.
ZN 1
GND
2
ZN 2
Figure 13: N/O No EOL Zone
Bosch Security Systems 10/12 BLCC600R
N/C
ZONE 1
ZONE 2
N/C
ALARM
N/C
ZONE 1
N/C
ALARM
N/C
ALARM
ZONE 1
(3K3 EOL)
N/C
ALARM
ZONE 9
(6K8 EOL)
TAMPER
(6K8 EOL)
N/C
TAMPER
ZONE 1
N/C
ALARM
(3K3 EOL)
N/O
ZONE 1
ZONE 2
N/O
ZN 1
GND
ZN 2
ZN 1
GND
ZN 2
ZONE 2
ZN 1
GND
ZN 2
EOL R e si stor Col our s a nd Val ue s
Use either the 4 colour, or solid colour resistors supplied.
3K3
6K8
3K3 =
6K8 =
Solution 144 Quick Start Guide
ALARM
N/O
N/O
ALARM
Figure 14: N/O Single EOL Zone
N/O
ALARM
N/O
ALARM
Figure 15: N/O Split EOL Zone
TAMPER
(6K8 EOL)
N/C
TAMPER
ALARM
Figure 16: N/O Zone With Tamper
Orange
Orange
Grey
Blue
Orange
Blue
Figure 17: EOL Resistor Colour Chart
ZONE 1
ZONE 2
ZONE 1
(3K3 EOL)
ZONE 9
(6K8 EOL)
ZONE 1
N/O
(3K3 EOL)
Red
Brow n (+/- 1%)
Red
Brow n (+/- 1%)
9