Connecting Power To The Panel; Connecting The Battery; Ac Mains Transformer Option; Panel Led Indicators - Bosch Solution 144 Quick Start Manual

Hide thumbs Also See for Solution 144:
Table of Contents

Advertisement

Solution 144
Quick Start Guide
Con n ec t in g Power To Th e Pan e l
For normal operation, the panel requires both AC and DC
power sources. The AC source can be provided either by an
external adapter or by an internal transformer depending
on the model and country of sale.
When connecting using the AC adapter, feed the cable in
to the enclosure and terminate the wires on the removable
terminal block supplied before connection it to the PCB.
If using a 3 wire adaptor, then the earth wire should also
be terminated onto the terminal block. Always check the
orientation of the terminal block with the PCB markings
before connecting it to the PCB.
Con n e c t in g Th e B at te r y
The panel is supplied with a set of battey leads to suit the
chosen enclosure. Connect the RED battery lead to the
battery (+) terminal and the BLACK battery lead to the
battery (-) terminal on the PCB.
Once terminated onto the PCB connect the other end of
the leads to the battery paying attention to the polarity.
AC M a in s Tra nsfor m e r O pt i o n
On models with an internal transformer, a permanent
connection shall be made to the mains supply. See
Figure 8. This must be completed by a suitably qualified
electrician according to the applicable wiring standards
and regulations.
Next connect the transformer output wires (red) to the
removable terminal block supplied and then connect it
to the PCB. Always check the orientation of the terminal
block with the PCB markings before connecting.
For permanently connected equipment, a readily
i
accessable disconnect device shall be installed in a
Note
location near to the equipment.
8
Transformer Output
(Red Wires)
A
Transformer
D
(Blue Wires)
A
B
A = PCB Mounting Clip Holes
B
= Enclosure Mounting Holes
C
= Fused Terminal Block
D
= Transformer

Figure 8: Internal Transformer Connection Diagram

Pane l L ED I n dic ator s
The control panel PCB has two LED indicators (Dialler and
Status LED's) which display the following information.
Condition
Off
On
Flashing

Table 2: Dialler Indicator LED

Condition
Off
On
Flash Once Every 2 Seconds
Flash Fast

Table 3: Status Indicator LED

During factory defaulting the Status and Dialler LED
i
indicators will flash alternatively for approximately
Note
15 seconds.
Bosch Security Systems 10/12 BLCC600R
Wiring must be carried out by
a licensed electrician following
applicable wiring standards
Input
TRANSFORMER
220 - 240V A.C.
50-60Hz 150mA
FUSE
8AG - 250V
250mA MAX
NEUTRAL
EARTH
ACTIVE
C
Meaning
Offline
On Line (Dialling/Answered)
Incoming Call
Meaning
Error
Error
OK
AC or Battery Trouble
A
A

Advertisement

Table of Contents
loading

Table of Contents