When an electricity meter is connected
At electricity apportionment, the DX-Kit itself and units [A] and [B] mentioned above can be handled
the same as when an electricity meter is not connected.
Set the electricity value at ON beforehand for the units [A] and [B] from the "Parameter Setting" screen
and install the electricity meter so that the units [A] and [B] are included.
The input value in the calculation as a constant value when the external output value is ON is included.
DX-Kit
DX-Kit
If there is a unit related to the DX-Kit other than [A] and [B], if the DX-Kit is connected as an indepen-
dent electricity meter system and installed so that other units are included, it may be included in elec-
tricity charge apportionment. (All the value of that electricity meter is charged to the DX-Kit.)
DX-Kit
DDC/Damper/Heater, etc.
Whm
Units other than [A] and [B] must not be connected to an electricity meter together with other indoor
units. If connected, the electricity amount of DDC, damper and heater is also charged to the other
indoor units.
DX-Kit
DDC/Damper/Heater, etc.
Copyright© 2013-2015 Fujitsu General Limited. All rights reserved.
Whm
[B] External fan
[A] Run/stop state
External output linked units
Whm
[B] External fan
[A] Run/stop state
External output
Whm
linked units
Whm
[B] External fan
[A] Run/stop state
External output linked units
Whm
[B] External fan
[A] Run/stop state
External output linked units
297
The electricity meter is installed so that
the units [A] and [B] are included.
The electricity meter is installed indepen-
dently from the units [A] and [B].
The electricity meter is installed so that
[A], [B], and other units are included.
The electricity meter is installed so that
the units other than [A], [B] and indoor
units are included.