10.9.2 ME – RESET – EQUIPMENT
Machine Equipment.
Parameter which the engineer can force restoration of the
equipment values to the factory values.
This resets all the equipment values.
The default setting of the parameter is "UV" (user values)
if the values have been changed from the factory values.
To restore the configuration and equipment values to the
Factory values, set and confirm "FV".
[change value with P2/P8, confirm with P5]
10.9.3 DF – Dryer filter – Relative decremental counter
DF:
Filter hours remaining.
The parameter indicates, to the nearest ten, the
number of fan operating hours left before filter
replacement.
Initial value 50 ("DF 50" on the display means 500
hours), which counts down with use:
49, 48... down to 0 (Zero).
The value can be reset by an authorised engineer.
When Zero is reached: the code changes from
DF (Dryer Filter) to DFW: (Dryer Filter Warning).
The numerical value which follows, e.g. "DFW:01",
corresponds to the tens of operating hours after zero
was reached (in this case 510 hours), DFW:02... up to
DFW:99, the value at which the counter stops.
To reset the value:
authorised engineer, by holding down button P5.
The value is returned to the default value (DF-50)
and the countdown restarts.