Power Cord Installation - Wolf CSO24TE/S General Information Manual

Table of Contents

Advertisement

Back Component Removal and Installation
INSTALL THE TOP PLATE (continued)
2
Use a T-20 Torx bit to install the screws into the top plate.
POWER CORD REMOVAL
To remove the power cord, first remove the top plate.
Remove the Top Plate
1
Use a T-20 Torx bit to remove the screws from the top and
back of the unit.
2
Remove the top plate from the unit.
Remove the Power Cord
1
Disconnect the power cord electrical connectors from the
unit relay board and the back of the unit.
2
Remove the cable protector from the power cord.
3
Compress the cable clamp and push it down out of the unit.
4
Remove the power cord from the unit.

POWER CORD INSTALLATION

827703 REV B.1
CSO (SWS #13543126)
Install the Power Cord
1
Install the cable clamp onto the power cord.
2
Place the cable clamp and power cord in the unit.
3
Install the cable protector onto the power cord.
4
Connect the power cord electrical connectors to the unit
relay board and the back of the unit.
Install the Top Plate
1
Place the top plate on the unit.
2
Use a T-20 Torx bit to install the screws into the top plate.
UNIT RELAY BOARD REMOVAL
To remove the unit relay board, first remove the top plate.
Remove the Top Plate
1
Use a T-20 Torx bit to remove the screws from the top and
back of the unit.
2
Remove the top plate from the unit.
Remove the Unit Relay Board
1
Disconnect the electrical connectors from the unit relay
board.
2
Open the spacers one at a time, and pull the unit relay
board forward.