Wolf CSO24TE/S General Information Manual page 79

Table of Contents

Advertisement

Back Component Removal and Installation
REMOVE THE TOP PLATE (continued)
2
Remove the top plate from the unit.
Remove the Evaporator
1
Disconnect the hose that goes to the drain pump suction.
2
Disconnect the condenser water nozzle from the
evaporator.
3
Disconnect the electrical connectors to the evaporator.
4
Disconnect the electrical connector to the level measure
pin.
5
Disconnect the electrical connector to the temperature
sensor.
6
Use a flat-blade screwdriver to press in the tab above the
evaporator.
7
Lift the evaporator from the retaining brackets.
8
Remove the evaporator from the unit.
EVAPORATOR INSTALLATION
Install the Evaporator
1
Connect the electrical connector to the temperature sensor.
827703 REV B.1
CSO (SWS #13543126)
2
Insert the evaporator into the retaining tabs on the unit.
3
Use a flat-blade screwdriver to pry out the tab over the
evaporator.
4
Connect the condenser water nozzle to the evaporator.
5
Connect the hose from the evaporator to the drain pump
suction.
6
Connect the electrical connector to the level measure pin.
7
Connect the electrical connectors to the evaporator.
Install the Top Plate
1
Place the top plate on the unit.
2
Use a T-20 Torx bit to install the screws into the top plate.
LEVEL MEASURE PIN REMOVAL
To remove the level measure pin, first remove the top plate and
evaporator.
Remove the Top Plate
1
Use a T-20 Torx bit to remove the screws from the top and
back of the unit.
2
Remove the top plate from the unit.
Remove the Evaporator
1
Disconnect the hose that goes to the drain pump suction.
2
Disconnect the condenser water nozzle from the
evaporator.
3
Disconnect the electrical connectors to the evaporator.
4
Disconnect the electrical connector to the level measure
pin.
79