Back Component Removal and Installation
Food Probe Socket Removal (continued)
FOOD PROBE SOCKET REMOVAL
To remove the food probe socket, first remove the racks, right-
hand rack guide, and food probe cover.
Remove the Rack
Pull the rack forward out of the unit.
Remove the Rack Guide
1
Remove the rack guide nut.
2
Pull the front of the rack guide toward the center of the
oven.
3
Pull the rack guide forward out of the unit.
Remove the Food Probe Cover
1
Lift the food probe cover.
2
Use an 11 mm socket to remove the food probe cover nut.
3
Remove the food probe cover, nut, and food probe cover
seal from the unit.
827703 REV B.1
CSO (SWS #13543126)
Remove the Food Probe Socket
1
Use diagonal pliers to cut across the front joints of the food
probe socket cover.
2
Lift the front of the food probe socket cover and bend it
toward the back of the unit.
3
Disconnect the electrical wires from the food probe socket.
4
Remove the food probe socket from the unit.
FOOD PROBE SOCKET INSTALLATION
Install the Food Probe Socket
1
Connect the electrical wires to the food probe socket.
2
Insert the food probe socket into the unit.
a) Place the food probe seal onto the food probe cover.
b) Place the food probe cover over the food probe switch
threads.
c) Use an 11 mm socket to install the food probe nut.
3
Bend the food probe socket cover back into place.
4
Cover the food probe socket cover with aluminum tape.
82