Error Code
Error
E87/F4
Slider blocked.
E88
Slider in stop position.
E89/F18
Communication
interruption - inverter.
E90/F18
The temperature
reading of the inverter
heat sink is defective.
E91/F18
Temperature
measurement of
magnetron defective.
E92/F18
Magnetron heating coil
defective.
E93/F18
Defective microwave
anode distance
system.
E94/F19
Inverter hardware
defective.
E95/F18
Insufficient cooling of
magnetron.
E97
Operating system:
Watchdog control
board.
E98
Operating system:
Watchdog relay board.
E99
Operating system:
ASSERT control board.
E100
Operating system:
ASSERT relay board.
E101/F30
No communication
with control board.
E102/F30
No communication
with relay board.
E103/F31
Operating system:
Communication
between relay board
and control board is
incompatible.
E104/F31
Operating system:
CORE incompatible.
E105
Operating system:
NVRAM-FLASH-PAGE
write error.
E106
Operating system:
NVRAM-FLASH-PAGE
delete error.
827703 REV B.1
Possible Cause
Test/Action
2
3
4
Slider path restricted
1
during operation.
2
Slider path restricted
1
during operation.
2
Not applicable to Wolf products.
Not applicable to Wolf products.
Not applicable to Wolf products.
Not applicable to Wolf products.
Not applicable to Wolf products.
Not applicable to Wolf products.
Not applicable to Wolf products.
Replace the control board.
Replace the relay board.
Moisture on control
1
board.
2
Moisture on relay
1
board.
2
1
2
3
1
2
3
Software version of
Replace the control board and relay board.
relay board and control
board incompatible.
Replace the control board and relay board.
Moisture on control
1
board.
2
Moisture on control
1
board.
90
CSO (SWS #13543126)
Measure the resistance of the stepper motor.
Replace the stepper motor.
Replace the relay board.
Slider blocked with grease.
Slider mechanism is too tight. Replace the slider.
Slider blocked with grease.
Slider mechanism is too tight. Replace the slider.
Inspect the control board for moisture.
Replace the control board if the error continues.
Inspect the relay board for moisture.
Replace the relay board if the error continues.
Inspect the connection between the relay board
and control board.
Replace the control board.
Replace the relay board.
Inspect the connection between the relay board
and control board.
Replace the relay board.
Replace the control board.
Inspect the control board for moisture.
Replace the control board if the error continues.
Inspect the control board for moisture.