Perc Module; Removing The Fperc Module; Installing The Fperc Module - Dell PowerEdge XR7620 Installation And Service Manual

Table of Contents

Advertisement

PERC module

This is a service technician replaceable part only.

Removing the fPERC module

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3. Disconnect all the cables, observe the cable routing.
NOTE:
Refer to
cable routing
NOTE:
The procedure to remove the fPERC module is the same for Rear Accessed and Front Accessed configurations.
Steps
1. Using a Phillips 2 screwdriver, loosen the captive screws on the fPERC module.
2. Slide the fPERC module to disengage from the connector on the drive backplane.
Figure 65. Removing the fPERC module
Next steps
1.
Replace the fPERC
module.

Installing the fPERC module

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in
3. Route the cable properly to prevent the cable from being pinched or crimped.
NOTE:
Refer to
cable routing
98
Installing and removing system components
Safety
instructions.
Before working inside your
section for more information.
Safety
instructions.
Before working inside your
section for more information.
system.
system.