Dell PowerEdge XR7620 Installation And Service Manual page 59

Table of Contents

Advertisement

Table 63. TLS Authentication Configuration screen details 
Option
TLS Authentication Mode
Root Certificate Configuration
Table 64. NVMe-oF SubSystem Settings screen details 
Option
NVMe-oF SubSystemn (n = 1 to 4)
NVMe-oF SubSystemn Settings (n = 1
to 4)
Table 65. NVMe-oF SubSystem n Settings 
Option
Interface
Transport Type
Protocol
VLAN
VLAN ID
VLAN Priority
Retry Count
Timeout
DHCP
Host IP Address
Host Subnet Mask
Host Gateway
NVMe-oF Subsystem info via DHCP
NVMe-oF Subsystem NQN
NVMe-oF Subsystem Address
NVMe-oF Subsystem Port
NVMe-oF Subsystem NID
NVMe-oF Subsystem Controller ID
Description
View or modify the device's boot TLS Authentication Mode. This option is set to One
Way by default. None means the HTTP server and the client will not authenticate each
other for this boot.
Import, delete, or export the root certificate.
Description
Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Description
NIC interface used for NVMe-oF connections. This option is set to Embedded
NIC 1 Port 1 Partition 1 by default.
This field sets the value of transport type for NVMe-oF connection. This option is
set to TCP by default.
This field sets the value of protocol type for NVMe-oF connection. This option is
set to IPv4 by default.
Enables or disables VLAN for this NVMe-oF connections. This option is set to
Disabled by default.
Specifies the VLAN ID for this NVMe-oF connection. This option is set to 1 by
default.
Specifies the VLAN priority for this NVMe-oF connection. This option is set to 0 by
default.
Specifies the retry count for this NVMe-oF connection. This option is set to 3 by
default.
Specifies the time out for this NVMe-oF connection. This option is set to 10000 by
default.
Enables and disables the DHCP for this NVMe-oF connection. This option is set to
Disabled by default.
Specifies the Host IP Address for this NVMe-oF connection.
Specifies the Host Subnet Mask for this NVMe-oF connection.
Specifies the Host Gateway for this NVMe-oF connection.
Enables and disables the NVMe-oF subsystem's DHCP for this connection. This
option is set to Disabled by default.
Specifies the NVMe-oF subsystem's NQN for this connection.
Specifies the NVMe-oF subsystem's IP address for this connection.
Specifies the NVMe-oF subsystem's port for this connection. This option is set to
4420 by default.
Specifies the NamespaceID (NID) for this NVMe-oF connection.
Specifies the NVMe-oF subsystem's Controller ID for this connection. This option
is set to 0 by default.
Pre-operating system management applications
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

E89s

Table of Contents