2. Run the BOOTP and TFTP Servers followed by device reboot
When the device reboots, the device gets the IP Address and Boot filename from the BOOTP server. You need not change any
of the default Bootloader parameters. After BOOTP succeeds, the device initiates a TFTP request with the filename it gets
from BOOTP.
To load the Firmware by using Static IP Parameters
1. Use the set command to set the IP parameters like 'ipaddr', 'serverip', 'filename' and also set the parameter
'ipaddrtype' to static.
2. Run the TFTP Server followed by device reboot.
When the device reboots, the TFTP request is initiated with the value taken from the parameter "filename". This request is
sent to the IP address set as "serverip". In this case, the TFTP Server should be reachable to the device.
ScanTool
If you want to access the device with ScanTool, then the host running the ScanTool should also be in the same network as the
device. The ScanTool broadcast requests are discarded by the routers if the device and the host running the ScanTool are in
different networks. This means that the ScanTool cannot discover the device.
: In bootloader mode, Scan Tool will support only IPv4.
A device in Bootloader can be recognized by looking at the system description. If the system description does not contain any
build number in braces, conclude that the device is in Bootloader mode.
For example:
MP-10100-BSU
WD
v6.3.0
SN-SN000000000000121212
BL-V1.0.4
Device Management Guide
- Description of the device
- Regulatory Domain
- Firmware Version
- Serial Number
- Bootloader version
Figure 8-1 Scan Tool View of a Device in Bootloader Mode
A Bootloader CLI and ScanTool