Device Capabilities - AutomationDirect StrideLinx SE-SL30011 User Manual

Industrial vpn router with stridelinx cloud 2.0
Table of Contents

Advertisement

Linx
Appendix F: Capabilities of Connected AutomationDirect Devices

Device Capabilities

The following table describes the capabilities of devices to establish communications
connections across various network zones, as defined earlier.
Communications Capabilities of Devices Connected to StrideLinx Router
Generic PLC programming SW
Productivity programming SW
BRX programming SW
CLICK programming SW
C-more programming SW
C-more Remote Access (PC)
PxK/C-more web server
PxK/C-more FTP access
BRX/PxK/C-more Email to Server
(sent from BRX/PxK/C-more)
PxK/C-more FTP to PC
(sent from PxK/C-more)
PxK/C-more mobile app
3rd party PLC or HMI web/VNC server
Windows-based machine control
2nd StrideLinx Router
(M2M or site-to-site)
1. Connections from Zone 2 to 3 can be made through VPN on a PC but require firewall adjustments (port forwarding) for other
devices. Consideration for security should be made before making firewall adjustments.
2. StrideLinx router firewall must be configured to allow internet access from the LAN side or allow access to corporate network.
This data does not pass through the VPN tunnel.
3. StrideLinx router firewall must be configured to allow access to corporate network in order for the C-more Mobile App to connect.
4. PxK/C-more web server must be configured in StrideLinx Cloud (services tab) to provide the shortcut on the router dashboard
page.
5. Web/VNC server capability depends on 3rd party device capability. Web/VNC server must be configured in StrideLinx Cloud
(services tab) to provide the shortcut on the router dashboard page.
6. Connections to/from Zone 2 are not applicable when using a 4G cellular connection.
7. NA is used when the device is not located in the starting or ending zone.
8. Router firmware versions v3.13 and newer support connection from the C-more Mobile App across a mobile VPN tunnel (app
versions 2.0.0 and newer).
NOTE: The StrideLinx router & cloud should operate with any TCP/UDP Ethernet device designed with remote
connectivity functions such as unicast messaging, default gateway support and retry timeout parameters. ADC tech
support can assist with basic networking/connectivity troubleshooting for any device connected to a StrideLinx router,
but only officially supports ADC hardware and programming software tools.
StrideLinx™ Cloud 2.0 Industrial VPN Routers User Manual
Functionality
(StrideLinx App or
Browser w/o VPN)
(Windows)
(into PxK/C-more)
(connect by WiFi)
Zone 1->3
Zone
1->3
(VPN)
N
Y
N
Y
N
Y
N
Y
N
Y
N
Y
4
Y
Y
N
Y
NA
NA
NA
NA
8
N
Y
5
Y
Y
N
Y
NA
NA
Zone
Zone
Zone
1,6
6
2->3
3->2
3->1
Y
NA
NA
Y
NA
NA
Y
NA
NA
Y
NA
NA
Y
NA
NA
Y
NA
NA
Y
NA
NA
Y
NA
NA
2
2
NA
Y
Y
2
2
NA
Y
Y
3
Y
NA
NA
Y
NA
NA
Y
NA
NA
NA
NA
N
1st Edition Rev. C
Zone
3->3
Y
Y
Y
Y
Y
Y
Y
Y
NA
NA
Y
Y
Y
NA
F-5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StrideLinx SE-SL30011 and is the answer not in the manual?

Questions and answers

Table of Contents