4.2.6.2 Voltage output to supply the inputs
Specification voltage output
ma_dr_s6-cu-p-inst-20156056_en
Connection of the external supply
The control card is supplied by an external 24 V voltage. An internal
supply via a voltage generated in the power section is not provided.
When using the
maintained until the function has been completed. Further information
in the programming manual under "Power-Off function".
Name
Terminals
Output current
Output voltage
Notes
Connection see (≡►
Digital Inputs
Connection of the control | 4
28
X2A
27
-
+
Power-Off
function, the external 24V supply must be
24Vout
0V (reference potential)
X2A.16, X2A.26 (24Vout)
X2A.27 (0V)
max. 100 mA (short-circuit proof)
total for both terminals
minimum P24Vin – 3V
maximum P24Vin
DC voltage output
digital inputs; Terminals are internally
parallel connected.
[} 20])
(SELV
) to control the