Vcc - Led; Net St - Led; Dev St - Led; Opt - Led - KEB COMBIVERT S6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT S6:
Table of Contents

Advertisement

3 | Product description
3.13.2 VCC - LED
3.13.3 NET ST - LED
3.13.4 DEV ST - LED
3.13.5 OPT - LED
16
LEDs
Status
VCC
off
NET
ST
DEV
ST
OPT
VCC
Initialization
NET
ST
DEV
ST
OPT
VCC
ready for operation
NET
ST
DEV
ST
OPT
Tab. 3: LEDs at power on
VCC
LED colour Description
off
-
Power supply of the control card switched off.
on
green
Control is supplied with 24 V.
Tab. 4: Function VCC LED
NET ST
LED colour Description
off
-
Device off or booting.
Blink
various
depending on fieldbus => fieldbus interfaces.
code
Tab. 5: Function NET ST - LED
DEV ST
LED colour Description
OFF
-
Device off or in boot process.
ON
Red
Error
ON
Yellow
No error, DC bus not charged.
ON
Green
No error, ready for operation.
Flashing
Green
No error, serves to identify the device (fb.32).
Tab. 6: Function DEV ST - LED
OPT
LED colour Description
-
-
reserved for options.
Tab. 7: Function OPT - LED
Note
Device off
Control is supplied with 24 V
Device is ready for operation and the LEDs start
with their normal function (approx. 3 s)