Target Selection Mode; Reset The Sensor To Factory Defaults; Factory Default Settings - Banner R-GAGE Q90R Instruction Manual

Radar sensor
Table of Contents

Advertisement

Q90R R-GAGE® Radar Sensor Instruction Manual
Action
Pulses
1
2
3
5.5.5

Target Selection Mode

Use Target Selection to set the target that the output sees.
1.
Access Target Selection mode.
Five-pulse the remote input.
2.
Select the desired signal threshold.
Action
Pulses
1
2
5.6

Reset the Sensor to Factory Defaults

Reset the sensor to factory default settings using one of two methods.
NOTE: If a factory reset is performed through the Banner Radar Configuration Software, the remote input
wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the
remote input wire, the input wire remains enabled and the rest of the settings are restored to factory
defaults.
To reset using the Banner Radar Configuration software, go to Sensor › Factory Reset. The sensor indicators flash once, the
sensor is reset back to the factory default settings, and a confirmation message displays.
To reset using the remote input, eight-pulse the remote input to apply the factory defaults.
5.7

Factory Default Settings

Table 5.
General Tab Default Settings
Response Speed
Signal Strength Threshold
Target Mode
Measurement Hold
Discrete Output & Remote Input
Remote Input Wire
20
T
Speed = Fast
T
T
Speed = Medium
T
T
T
T
Speed = Slow
T
T
Action
Nearest Target—Output responds
T
to the nearest target that is over the
signal strength threshold.
Strongest Target—Output responds
T
T
to the target with the highest signal
strength that is over the signal
T
strength threshold.
Setting
© Banner Engineering Corp. All rights reserved.
TEACH Mode
The speed is set and the power LED flashes equal
to the number of pluses, pauses, and then flashes
equal to the number of pulses a second time. The
sensor exits remote teach and returns to run mode.
T
T
T
T
T
The green power LED flashes slowly.
T
T
T
T
TEACH Mode
The signal threshold is set and the green power
LED flashes equal to the number of pluses,
pauses, and then flashes equal to the number of
pulses a second time. Then the sensor exits
remote teach and returns to run mode
Factory Default
Medium
1.0
Nearest Target
Disabled
PNP
Disabled
Result
Result
Result
February 12, 2024

Advertisement

Table of Contents
loading