E1/E20 Emulator
(a)
(a) Host-side connector:
(b) Host-side connector mark:
(c) Power switch (E20 only):
Figure 1.5 E1 and E20 Host-Side View
(a)
(a) User-side connector:
(b) User-side connector mark:
Figure 1.6 E1 and E20 User-Side View
1.8. Operating Environment
Observe the conditions listed in Table 1.4 when using the emulator.
Table 1.4 Operating environmental conditions
Item
Temperature
Humidity
Vibration
Ambient gases
R20UT0398EJ0401 Rev.4.01
Mar 15, 2016
E1 Emulator
(b)
A USB connector for the host computer.
Be sure to connect the provided USB interface cable.
Marked "
A connector for the host computer is provided at the side of this mark.
Power switch of the emulator.
When the switch is shifted to "|", the power is on. Shifting the switch to "", on
the other hand, turns off the power.
The USB supplies power to the emulator.
E1 Emulator
(b)
USER I/F
A user-system interface cable is connected.
Marked 'USER I/F'.
A connector for the user-system interface cable is provided at the side of this
mark.
Operating: +5°C to +35°C
Storage: –10°C to +60°C
35% RH to 80% RH, no condensation
Operating: 2.45 m/s2 max.
Storage: 4.9 m/s2 max.
Transportation: 14.7 m/s2 max.
No corrosive gases may be present
(c)
I
".
(a)
Description
E20 Emulator
(a)
O
E20 Emulator
(b)
USER I/F
Page 17 of 40
Outline
(b)