Chapter 1-6
Short press will toggle between active pages under the main function
PAGE
keys. Long press will start automatic rotation of these pages (see sec-
tion 2.1). Press any key to stop rotation.

1.3.2 Radar and radar functions

Press the [RADAR] key to call up a radar display. Press again to
RADAR
toggle between the radar shortcut series
- see display examples in section 1.3.1.
To start the radar
1. Press [ENT], [RADAR] to initiate a warming up period of two minutes
(countdown of 120 seconds), and then the radar will go in Standby mode.
2. Press [ENT], [GOTO] to start transmission.
Select and adjust radar range
Press one of the numeric keys 1 - 9 to select a fixed range. Key 9 will select
the largest range and key 1 the smallest.
Press [ENT] to call up the Radar quick menu with access to e.g.
ENT
Overlay Chart, Overlay User Data, activate EBL-VRM cursors, start
and stop radar transmission, etc.
Toggle the EBL-VRM1 cursors on/off directly from the [EBL] key.
EBL
Turn off cursor. Long press on [CLR] will turn off all cursors on the
CLR
radar screen.
The [ADJ] key will open for adjustment of the radar parameters.
ADJ
Use the cursor or the [ADJ] key to move around in the control panel;
toggle between available values with the +/- keys or enter new values
with the numeric keys. Press [ENT] to exit control panel.
In the Dual Radar display: after pressing the [ADJ] key to access the
control panel, only half of the parameters will be visible. By pressing
[ADJ] again will toggle between the 1st and 2nd half of the control
panel.
Introduction and safety summary