Problem Detected: STANDING BY LED (Blinking)
The AQR100 has shut down because the temperature of the pool/spa water is too high
(120ºF) or too low (50ºF).
The system will not resume operation until the water temperature returns to normal.
Inspect Cell Cord Connection
Confirm water temperature
Step 1G
Step 2G
Inspect cell cord
Inspect cell pins for
Desired
for damage or
water damage or
corrosion
corrosion
Water
Temperature
is between
65°F
-
104°F
Cell cord must be connected securely and be free of
Confirm water temperature is between 50ºF and 120ºF.
damage. Check the cell/cable connector for water
Remove power to the AQR100 for two minutes.
intrusion. Grease connection and reconnect. If error does
Re-apply power to reset the system. If error does not clear
not clear replace the cell.
go to step 2G.
* NOTE: This condition can sometimes happen if the pool/spa
temperature is already high, and the heater is running. The
temperature coming out of the heater and into the Cell could
possibly be high enough to shut down the AQR100.