Problem Detected: LED #4
These lights illuminated together indicate a Temperature Sensor Error.
Inspect Cell
Remove Power From AQR100
Step 4C
Step 4D
Remove
calcium and
other debris
from the cell
Turn power off for 2
minutes, then backon
Remove power from the AQR100 for two minutes.
Cell should be clean & free of debris. If cell is dirty, clean
Re-apply power to reset the system. If error does not
the cell.
clear go to step 4D.
If cell is clean, replace cell (CCELL).
45