No LED's On Display (Cont.)
No LED's indicate a loss of power to/within the AQR100
Remove Front Cover
Check 20a Fuse
Step 1E
Step 1F
Slowly separate the front cover from the back of the
Remove yellow 20a fuse and test for continuity. If fuse is
AQR100 and move it towards the top of the unit. Be
bad replace it (GLX-F20A-10PK), restore power, check for
mindful not to damage the membrane cable as itwill
display LED's. If fuse is good and no LED's are on, go to
remain connected to the PCB. Go to step 1F.
step 1G. If LED's come back on re-assemble AQR100.