Problem Detected: LED #5,6,7, or 9
Problem Detected with any one of these LED's illuminated indicates an Internal Error.
LED #5,6,7, or 9
Flashing
(Internal Error)
Clean filter or
NO
clear plumbing
obstruction
47
Remove power
for 2 mins then
re-apply
Replace PCB
(GLXAQR100PCB)
NO
NO
YES
Did error clear?
YES
Does moving
water fully cover
cell Plates?
*For verification of diagnosis contact Hayward Technical Support
Did error clear?
YES
Problem solved
YES
NO
Did error clear?
908-355-7995
Is salt level
NO
below
4500ppm?
NO
Dilute salt level
to lower than
4500
YES
Did error clear?
NO
Is water
YES
temperature
below 104°F?
NO
Wait until water
temperature falls
below 104°F