How To: Test/Replace Cell Cord (Cont.)
Test Cable Continuity
Test Cable Continuity
Top center
terminalnot
used
Use a multi-meter to test continuity of cell cablewires.
With lead in place at cell plug terminal, use other lead to
Place one lead into a wire terminal. Make note of the
test each terminal of the cell cable cap. *Only the
color of wire at the terminal. The other meter lead will
matching wire terminal should have continuity. If one
be used at the cell cable cap terminal. Be sure to verify
wire shows continuity in multiple terminals , replacethe
proper continuity at each wire terminal.
cell cable (GLXAQR100CCABLE). Go to next step.
*Terminals at cell cable cap are NOT actually color coded.
Verify proper orientation of cap while testing continuity.