Problem Detected and MIN LED
When these lights illuminate together, the cell reports salt levels below 1500.
Test the Salt Level
Step 3A
Test the salt concentration of the water using an
independent test, with a calibrated salt meter. If thesalt
level is below 1500, raise the salt level
addition table pg.
The cleanliness of the Cell plays a major role in the AquaRite 100's ability to report salt levels
37
Desired Salt
Concentration:
1500-4500 PPM
(refer to salt
54). If fine, go to step 3B.
Inspect the Cell
Step 3B
Remove
calcium and
other debris
from the cell
The cell must be clean in order to report an accurate salt
reading. If the cell is dirty, clean thecell
(steps on
pg.11-12). If cell is clean, like the image above,
accurately.
go to step 3C.