Problem Detected: LED #8
These lights illuminated together indicate there is no current to the Cell.
Verify Moving Water Fully Covers Cell Plates
Inspect Cell Cord
Step 6D
Step 6C
Verify cell cord is
Inspect cell cord
for damage or
securely
fastened to cell
corrosion
*Cell cord must be connected securely and be free of
Inspect cell vessel and verify cell plates are fullycovered
damage, replace if necessary (GLXAQR100CABLE). **If
by moving water. Clear cell of any obstructions.
error does not clear replace the PCB (GLXAQR100PCB).
If problem persists, go to step 6D.
*Follow the steps on pages 13-18 to access/test/replace cell cable
53
**Follow the steps on pages 23-27 to access/test/replace PCB