Led Blinking - Hayward Salt & Swim® 3C Owner's Manual

Chlorine generator for inground swimming pools up to 30,000 gallons
Hide thumbs Also See for Salt & Swim® 3C:
Table of Contents

Advertisement

LED
BLINKING
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
and then plugging it back in.
2. Inspect the Cell. If dirty, follow the Cell cleaning procedure.
MIN LED
3. Check the salt level in the pool and verify the salt level is greater than
or
2600ppm but also less than 3400ppm.
LED 2
4. Inspect the Cell Vessel and verify the Cell plates are fully covered by moving
water.
5. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
and then plugging it back in.
LED 3
2. Verify that the Salt & Swim is receiving 120VAC input.
3. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
LED 4
and then plugging it back in.
2. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
and then plugging it back in.
LED 5
2. Check that the salt level in the pool is no greater than 3400ppm and/or the
or
temperature does not exceed 104F.
LED 6
3. Inspect the Cell Vessel and verify the cell plates are fully covered by moving
water.
4. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
LED 7
and then plugging it back in.
2. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
and then plugging it back in.
2. Inspect the Cell. If dirty, follow the Cell cleaning procedure.
LED 8
3. Inspect the
water.
4
. Inspect the cable that connects the cell to the system. Make sure the cable is
secure and undamaged.
5. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
LED 9
and then plugging it back in.
2. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
and then plugging it back in.
MAX LED
2. Inspect the cable that connects the cell to the system. Make sure the cable is
secure and undamaged.
3. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
Inadequate
and then plugging it back in.
2. Perform "Flow Switch Calibration" procedure.
Water Flow
2. Contact Hayward Technical Service.
1. Recycle power to the Salt & Swim by unplugging the linecord for two minutes
Standing By
and then plugging it back in.
2. Check that the pool temperature does is more than 50ºF and less than 104ºF.
2. Contact Hayward Technical Service.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
POSSIBLE ACTIONS
Cell Vessel
and verify the cell plates are fully covered by moving
17