With "MIN" LED
Reason
Verify salt level is between 1500 – 4500 ppm
Adjust salt level if necessary
Inspect cell. If dirty (calcified) then follow the
Low
Cell cleaning procedure
Salt
Inspect cell vessel, verify cell platesare
covered by moving water
Remove power to the AquaRite 100 for two
minutes, then re-apply to reset system
*Pages 34-39 will walk you through the proper steps to diagnose these errors
35
Problem Detected LED
Possible Action
With LED #2
Reason
Check the salt level in the pool is no greater
than 4500ppm
High
Verify water temperature is no greater than
104°F
Salt
Bring water temperature between
65°F -104°F if necessary
Remove power to the AquaRite 100 for two
minutes, then re-apply to reset system
Possible Action