Problem Detected With Led # 8 Or Max Led - Hayward AquaRite 100 Technical Training Manual

Salt chlorine generator
Hide thumbs Also See for AquaRite 100:
Table of Contents

Advertisement

With LED #8
Reason
Remove power to the AquaRite 100 for two
minutes and then re-apply to reset system
No
Turn on Super Chlorinate briefly then go back to
Current to
original setting
Cell
Inspect cell vessel and verify cell plates arefully
covered by moving water
*Pages 49-52 will walk you through the proper steps to diagnose these errors
50
Problem Detected LED
Possible Action
With "MAX" LED
Reason
Remove power to the AquaRite 100 for two (2)
minutes and then re-apply to reset system
Make sure cell cable is secure and free of
Cell Error
damage, replace if necessary (GLXAQR100CABLE)
If error persists, replace the cell
(CCELL)
Possible Action