Hayward AquaRite 100 Technical Training Manual page 54

Salt chlorine generator
Hide thumbs Also See for AquaRite 100:
Table of Contents

Advertisement

Problem Detected: MAX LED
These lights illuminated together indicate there is no current to the cell.
Inspect Cell Cord
Remove Power From the AQR100
Step 6E
Step 6F
Inspect cell cord
Verify cell cord is
for damage or
securely
corrosion
fastened to cell
Turn power off for 2
mins, then back on
*Cell cord must be connected securely and be free of
Remove power to the AQR100 for two minutes.
damage, replace if necessary (GLXAQR100CABLE). **If
Re-apply power to reset the system. If error does not
error does not clear replace the PCB (GLXAQR100PCB).
clear go to step 6F.
*Follow the steps on pages 13-18 to access/test/replace cell cable
54
**Follow the steps on pages 23-27 to access/test/replace PCB