Hayward AquaRite 100 Technical Training Manual page 51

Salt chlorine generator
Hide thumbs Also See for AquaRite 100:
Table of Contents

Advertisement

Problem Detected: LED #8 or MAX
LED #8 Flashing
(Low or no flow
condition)
Remove power
for 2 mins then
re-apply
MAX Flashing
(Water
Temperature
error)
Remove power
for 2 mins then
re-apply
YES
Did error clear?
NO
51
Briefly turn on
Super Chlorinate
then turn back
off
NO
YES
Did error clear?
Problem solved
YES
YES
NO
Did error clear?
YES
Is cell cable
NO
secure and free
of damage?
*For verification of diagnosis contact Hayward Technical Support
NO
Did error clear?
YES
Problem solved
YES
Replace Cell
(CCELL)
Replace Cell Cable
(GLXAQR100CABLE)
908-355-7995
Does moving
YES
water fully cover
cell plates?
NO
Clean filter or
clear obstruction
in plumbing
Did error clear?
YES
NO
Is the cable secure
Replace PCB
(GLXAQR100PCB)
Replace Cell Cable
(GLXAQR100CABLE)
NO
Did error clear?
YES
NO
and free of
damage?
NO

Advertisement

Table of Contents
loading

Table of Contents