Hayward AquaRite 100 Technical Training Manual page 43

Salt chlorine generator
Hide thumbs Also See for AquaRite 100:
Table of Contents

Advertisement

Problem Detected: LED #3 or #4
LED #3 Flashing
(Low input
power)
LED #4 Flashing
(Temperature
Sensor error)
Did error clear?
NO
Is cell clean and
free of debris or
calcium?
YES
43
Remove power
for 2 mins then
re-apply
Remove power
for 2 mins then
re-apply
YES
Clean cell using
NO
procedures on
pg. 11-12
*For verification of diagnosis contact Hayward Technical Support
Did error clear?
NO
Verify input power
is configured
correctly
Problem solved
YES
Did error clear?
908-355-7995
YES
Problem solved
YES
Did error clear?
NO
Replace
Transformer
(GLXAQR100XFMR)
NO
Replace Cell
(CCELL)

Advertisement