No LED's On Display (Cont.)
The rectifiers take AC voltage from the transformer and convert it to DC voltage for
both main board and chlorination functions.
Inspect Rectifier Wiring
Check Rectifier Voltage
Step 1KA
Step 1KB
*Cutoff Corner:
(Bottom Right)
YELLOW
YELLOW
*
*
OPEN
OPEN
Use your meter to test 30-32vdc at the rectifier plug on
Make sure the rectifiers are wired as shown above. IF the
the PCB. Test each pair of red and black wires as shown.
rectifiers are incorrectly wired, correct the wiring and
If voltage is not correct on both pairs replace rectifiers
retest. IF the rectifiers are wired, as shown above,
(GLXDRK). If it is correct go to step 1L.
proceed to step 1KB.
*Take note of the display ribbon cable position to verify proper re-installation
28