Stator Connector Assignment; Power Connector - LinMot P10-70-SSC-D Series Installation Manual

Linear motors
Table of Contents

Advertisement

Installation Guide Linear Motors

Stator connector assignment

Do not connect or disconnect motor when there is power on the servo drive.
Use only original LinMot cable. Cables from other sources must be checked precisely
before commissioning.
Incorrect connections can destroy the drive and stator.

5.2.1 Power Connector

Shielded motor cable d = 1.5 mm
Pin
P10-70-SSC
1
Phase U
2
PE
3
Phase W
4
Phase V
A
n.c.
B
n.c.
C
n.c.
D
n.c.
Pin
P10-70-SSC-D24
P10-70-SSC-D24S
1
Phase U
2
PE
3
Phase W
4
Phase V
1)
A
Pt1000+
1)
B
Pt1000-
C
n.c.
D
n.c.
Pin
P10-70-SSC-D34
1
2
3
4
A
B
C
D
1)
The temperature evaluation circuit must have the same galvanic reference potential as the encoder circuit
(supply). It should therefore be connected to the supply GND. For correct evaluation, the connection
potentials of the emulated temperature sensor must be in the range of the supply potentials. Valid
temperature values can only be measured 50ms after the encoder supply is applied. In currentless state a
resistance of 200kOhm is measured between pin A and B. The maximum voltage between pin A and B must
not exceed 16VDC. The maximum current is 15mA.
NTI AG / LinMot
2
P10-70-SSC-D04
Phase U
PE
Phase W
Phase V
Pt1000+
1)
1)
Pt1000-
n. c.
n. c.
P10-70-SSC-D25
P10-70-SSC-D25S
Phase U
PE
Phase W
Phase V
1)
PTC+
1)
PTC-
n. c.
n. c.
Phase U
PE
Phase W
Phase V
1)
Pt1000+
1)
Pt1000-
n.c.
n.c.
P10-70-SSC / P10-70-SSC-Dxx
P10-70-SSC-D05
Phase U
PE
Phase W
Phase V
PTC+
1)
1)
PTC-
n. c.
n. c.
P10-70-SSC-D26
Phase U
PE
Phase W
Phase V
Do not connect
Do not connect
n. c.
n. c.
Wire Color Motor Cable
yellow-green
black
purple
yellow
brown
ENG
Wire Color Motor Cable
red
yellow-green
black
blue
purple
grey
yellow
brown
Wire Color Motor Cable
red
yellow-green
black
blue
purple
grey
yellow
brown
red
blue
grey
Page 19 / 44