Determination Of The Max. Possible Amount Of Cont. Power Dissipation Pv_Max - LinMot P10-70-SSC-D Series Installation Manual

Linear motors
Table of Contents

Advertisement

Installation Guide Linear Motors

4.1.1 Determination of the max. possible amount of cont. power dissipation Pv_Max

First, the average temperature of the cooling water is set. The supply temperature will be slightly lower and
the return temperature slightly higher. Depending on the motor and the selected water temperature, the
maximum motor losses that need to be dissipated by the cooling result.
Example
Motor:
PS10-70x240U-SSC
T_Water:
25 °C
→ Pv_Max:
450 W
If the temperature of the cooling liquid is chosen to be lower than the ambient
temperature, there is a risk of condensation.
When used and stored in a frost-prone area, corrosion protection (e.g. Clariant) has to
be added.