Installation Guide Linear Motors
Item
Item No.
PLL01-28
0150-3094
7 Maintenance and test instructions
Stator connector assignment
Do not connect or disconnect motor when there is power on the servo drive.
Use only original LinMot cable. Cables from other sources must be checked precisely
before commissioning.
Incorrect connections can destroy the drive and stator.
7.1.1 Power Connector
Shielded motor cable d = 1.5 mm
Pin
1
2
3
4
A
B
C
D
Page 24 / 32
Material
Housing:
Bearing:
Slider
Thread
28mm
M5
2
P10-70-SSC
Phase U
Protective Earth
Phase W
Phase V
n.c.
n.c.
n.c.
n.c.
P10-70-SSC / P10-70-SSC-D02
Stainless steel 1.4305
Nitrile butadiene rubber
Spring steel DIN17223
d1
d2
d3
28mm
32mm
40mm
(1.10in)
(1.26in)
(1.57in)
P10-70-SSC-D02
Phase U
Protective Earth
Phase W
Phase V
n.c.
n.c.
n.c.
n.c.
ENG
D4
L
48mm
20mm
(1.89in)
(0.79in)
Wire Color
Motor Cable
Red
Yellow-Green
Black
(previously: Green)
Blue
-
-
-
-
NTI AG / LinMot