Determination Of Water Pressure  P; Corrosion Protection; Mounting - LinMot P10-70-SSC-D Series Installation Manual

Linear motors
Table of Contents

Advertisement

Installation Guide Linear Motors
4.1.3 Determination of water pressure  p
To achieve the water flow rate determined in 4.1.2, the hydraulic resistance of the cooling circuit in the motor
must be overcome. The maximum pressure difference across the motor's water connections can be
determined from the following diagram, which depends not only on the flow rate but also on the type of
motor.
Example
Q_Water: 1.6 l / min
→ ∆p:
2 bar

Corrosion protection

It is advised to add a corrosion protection into the cooling medium (water). A suitable agent can be, for
example, Protectogen C Aqua by Clariant. Information of the mixing ratio between the cooling medium and
the corrosion protection agent can be taken from the manufacturer's instructions.
Mixing of various corrosion protection agents is to be avoided.
Corrosion protection products must be matched to the materials of the cooling circuit
(see table of materials in the cooling circuit).

Mounting

The supply or conduction of the cooling medium to the stator is carried out via two connecting thread (see
illustration above). The connection can be realized by M5 push-in fittings.
NTI AG / LinMot
P10-70-SSC / P10-70-SSC-Dxx
ENG
Internal thread
M5 x 6.5
Connecting cross section
D = 4 mm (0.16 in)
Page 17 / 44