SUPERSERVER 6011H User's Manual
LVD Channel A SCSI Termination
Enable/Disable
Jumper JA2 allows you to enable or disable
termination for the LVD Channel A SCSI con-
nector. The normal (default) position is open
to enable SCSI termination. See the table on
the right for jumper settings.
LVD Channel B SCSI Termination
Enable/Disable
Jumper JA4 allows you to enable or disable
termination for the LVD Channel B SCSI con-
nector. The normal (default) position is open
to enable SCSI termination. See the table on
the right for jumper settings.

Thermal Fan Enable/Disable

JP65 allows you to enable or disable continu-
ous operation of the thermal fan. The default
position is open to disable continuous opera-
tion.
See the table on the right for jumper
settings.

VGA Enable/Disable

JP68 allows you to enable or disable the VGA
port. The default position is on pins 1 and 2
to enable VGA. See the table on the right for
jumper settings.

CPU/CPU Chassis Fan Select

JP72 allows you to select to use either the
CPU fan or the CPU Chassis fan. The default
position is closed to select the CPU fan. See
the table on the right for jumper settings.
5-22
LVD CH A SCSI
T ermination
Jumper Settings (JA2)
Jumper
Position
Definition
Open
Enabled
Closed
Disabled
LVD CH B SCSI
T ermination
Jumper Settings (JA4)
Jumper
Position
Definition
Open
Enabled
Closed
Disabled
T hermal Fan Enable/
Disable Jumper Settings
(JP65)
Jumper
Position
Definition
Open
Disabled
Closed
Enabled
VGA Enable/Disable
Jumper Settings
(JP68)
Jumper
Position
Definition
1-2
Enabled
2-3
Disabled
CPU/CPU Chassis Fan
Select Jumper Settings
(JP72)
Jumper
Position
Definition
Open
CPU Chassis
Closed
CPU