Problem
9. Control cycles continuous-
ly
10. Drain flows continuously
Need help? 1.800.390.5936
Cause
Internal control leak
Service adapter did not cycle
Misadjusted, broken, or shor-
ted switch
Valve is not programmed cor-
rectly
Foreign material in control
Internal control leak
43
Correction
Change seals, spacers, and piston as-
sembly
Check drive motor and switches
Determine if switch or timer is faulty
and replace it or replace complete power
head
Check control program and positioning of
control. Replace power head assembly if
not positioning properly
Remove power head assembly and in-
spect bore. Remove foreign material and
check control in various regeneration po-
sitions
Replace seals and piston assembly