13. Flow Meter Type (Display Code FM)
Press the Extra Cycle button. Use this display to set the type of flow meter connec-
ted to the control. This option setting is identified by "FM" in the upper left hand
corner of the screen. Use the Up and Down buttons to select one of the 7 available
settings:
t0.7
P0.7
t1.0
P1.0
t1.5
P1.5
P2.0
Gen
The 9500 valve will use "t1.5" for this setting.
14. End of Master Programming Mode
Press the Extra Cycle button to save all settings and exit Master Programming Mode.
USER PROGRAMMING MODE
Abbreviation
DO
Day Override
RT
Regeneration Time
H
Feed Water Hardness
RC or SF
Reserve Capacity
CD
Current Day
NOTE: Some times may not be shown depending on timer configuration. The timer
will discard any changes and exit User Mode if any button is not pressed for sixty
seconds.
User Programming Mode Steps
1.
Press the Up and Down buttons for five seconds while in service and the time of day
is NOT set to 12:01 PM.
Need help? 1.800.390.5936
User Programming Mode Options
Parameter
The time of day that the system will regenerate (meter delayed,
The hardness of the inlet water - used to calculate system capaci-
Fleck 3/4" Turbine Meter
Fleck 3/4" Paddle Wheel Meter
Fleck 1" Turbine Meter
Fleck 1" Paddle Wheel Meter
Fleck 1 1/2" Turbine Meter
Fleck 1 1/2" Paddle Wheel Meter
Fleck 2" Paddle Wheel Meter
Generic / Other Meter
Description
The timer's day override setting
timeclock, and day of week systems)
ty for metered systems
The fixed reserve capacity
The current day of week
38
www.uswatersystems.com