US Water Systems Synergy 9000 Installation Manual page 30

Table of Contents

Advertisement

Entering Master Programming Mode
Set the Time of Day display to 12:01 P.M. Press the Extra Cycle button (to exit Setting
Time of Day mode). Then press and hold the Up and Down buttons together until the
programming icon replaces the service icon and the Display Format screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings and cycle to the next
parameter. Press the Extra Cycle button at the last parameter to save all settings and
return to normal operation. The control will automatically disregard any programming
changes and return to normal operation if it is left in Master Programming mode for 5
minutes without any keypad input.
Resets
Soft Reset: Press and hold the Extra Cycle and Down buttons for 25 seconds while in
normal Service mode. This resets all parameters to the system default values, except
the volume remaining in meter immediate or meter delayed systems and days since
regeneration in the time clock system.
Master Reset: Hold the Extra Cycle button while powering up the unit. This resets all of
the parameters in the unit. Check and verify the choices selected in Master Programming
Mode.